ARDI
ARDI
Toggle navigation
You have no active alerts
View all
Guest
Guest
Login
Belt Press Filter A Dashboard
Home
Belt Press Filter A Dashboard
Description / Full Name
Coal Washery
/
Tailings Dewatering
/ Belt Press Filter A
Belt Press Filter
Level Monitored
Speed Controlled
Alarm
On BPF A Discharge Chute Blocked Switch
Chute Blocked
Alarm
On BPF-A Belt Drift - East
Drifting
Alarm
On BPF-A Belt Drift - West
Drifting
Alert - Faulted
On Belt Press Filter A Level Transmitter
There is an active fault on this device.
Alarm
On Belt Press Filter A Level Transmitter
Measurement Fault
Alarm
On FL4-53A Drive
Circuit Breaker Has Tripped
Alarm
On FL4-53A Drive
Control Supply Has Tripped
Alarm
On FL4-53A Drive
Drive Comms Fault
Alarm
On FL4-53A Drive
Drive Fault
Alert - Faulted
On FL4-53A Drive
There is an active fault on this device.
Alarm
On FL4-53A Drive
MCC Stop
Alarm
On FL4-53A Drive
Process Interlock
Alarm
On FL4-53A Drive
Run Contactor Fault
Alarm
On FL4-53A Drive
Thermal Overload
Tag
FL4-50A
PV Level
Monitored By Belt Press Filter A Level Transmitter
Bad Data
Actual Speed
Monitored By FL4-53A Drive
Bad Data
Setpoint Speed
Monitored By FL4-53A Drive
Bad Data
Drive Mode
Monitored By FL4-53A Drive
Bad Data
Drive Status
Monitored By FL4-53A Drive
Bad Data
Fault Code
Monitored By FL4-53A Drive
Bad Data
Drawing IDs
10028
Drawing Reference
G9
AR Marker
Test AR
Data Explorer
Click To View
Properties from Other Assets
Chute Status
From BPF A Discharge Chute Blocked Switch
Bad Data
Other Information
Isolation
Location
Show In VE
Location
Map
Media
Diagram
Maintenance
Comment
WA-MF
Validation
Data Validated
Monitored By FL4-53A Drive
No
Marker Validated
Monitored By FL4-53A Drive
No
Data Validated
From BPF-A Pull Wire - East
No
Data Validated
From BPF-A Belt Drift - West
No
Data Validated
From BPF A Discharge Chute Blocked Switch
No
Data Validated
From BPF-A Belt Drift - East
No
Data Validated
From BPF-A Pull Wire - West
No
Marker Validated
From BPF-A Belt Drift - West
No
Marker Validated
From BPF-A Belt Drift - East
No
Marker Validated
From BPF A Discharge Chute Blocked Switch
No
Marker Validated
From BPF-A Pull Wire - West
No
Marker Validated
From BPF-A Pull Wire - East
No
Ringline
Pull Wire
From BPF-A Pull Wire - West
OK
Pull Wire
From BPF-A Pull Wire - East
OK
Conveyor Drift
Drift
From BPF-A Belt Drift - West
Bad Data
Drift
From BPF-A Belt Drift - East
Bad Data
Relationships
Contains
Multiple Items
Is Inside
Tailings Dewatering
Is Integrated With
Multiple Items
Is Monitored By
Multiple Items
Is sent tailings from
Multiple Items
Is supplied water from
Multiple Items
sends rejects to
Belt Press Filter Discharge Chute A
sends tailings to
Belt Press Underpan - A
Show In 3D