ARDI
ARDI
Toggle navigation
You have no active alerts
View all
Guest
Guest
Login
Centrifuge G Dashboard
Home
Centrifuge G Dashboard
Description / Full Name
Coal Washery
/
Small Coal Dewatering
/ Centrifuge G
Centrifuge
Alarm
On CF3-41G2 Rotation Drive
Circuit Breaker Has Tripped
Alarm
On CF3-41G2 Rotation Drive
Control Supply Has Tripped
Alarm
On CF3-41G2 Rotation Drive
Isolator / E-Stop Active
Alarm
On CF3-41G2 Rotation Drive
MCC Stop
Alarm
On CF3-41G2 Rotation Drive
Process Interlock
Alarm
On CF3-41G2 Rotation Drive
Run Contactor Fault
Alarm
On CF3-41G2 Rotation Drive
Thermal Overload
Alarm
On CF3-41G3 Vibrator Drive
Circuit Breaker Has Tripped
Alarm
On CF3-41G3 Vibrator Drive
Control Supply Has Tripped
Alarm
On CF3-41G3 Vibrator Drive
Isolator / E-Stop Active
Alarm
On CF3-41G3 Vibrator Drive
MCC Stop
Alarm
On CF3-41G3 Vibrator Drive
Process Interlock
Alarm
On CF3-41G3 Vibrator Drive
Run Contactor Fault
Alarm
On CF3-41G3 Vibrator Drive
Thermal Overload
Alarm
On PU3-41G1 Pump Drive
Circuit Breaker Has Tripped
Alarm
On PU3-41G1 Pump Drive
Control Supply Has Tripped
Alert - Faulted
On PU3-41G1 Pump Drive
There is an active fault on this device.
Alarm
On PU3-41G1 Pump Drive
Isolator / E-Stop Active
Alarm
On PU3-41G1 Pump Drive
MCC Stop
Alarm
On PU3-41G1 Pump Drive
Process Interlock
Alarm
On PU3-41G1 Pump Drive
Run Contactor Fault
Alarm
On PU3-41G1 Pump Drive
Thermal Overload
Tag
CF3-41G
Data Validated
No
Marker Validated
No
Drawing IDs
10017
Drawing Reference
C10
AR Marker
Test AR
Data Explorer
Click To View
Properties from Other Assets
415 Phase A Voltage
From CB4-407 WC3
Bad Data
415 Phase B Voltage
From CB4-407 WC3
Bad Data
415 Phase C Voltage
From CB4-407 WC3
Bad Data
Motor Current
From CF3-41G3 Vibrator Drive
Bad Data
Motor Current
From CF3-41G2 Rotation Drive
Bad Data
Motor Current
From PU3-41G1 Pump Drive
Bad Data
Thermal Utilisation
From CF3-41G3 Vibrator Drive
Bad Data
Thermal Utilisation
From CF3-41G2 Rotation Drive
Bad Data
Drive Mode
From CF3-41G3 Vibrator Drive
Bad Data
Drive Mode
From PU3-41G1 Pump Drive
Bad Data
Drive Mode
From CF3-41G2 Rotation Drive
Bad Data
Drive Status
From PU3-41G1 Pump Drive
Bad Data
Drive Status
From CF3-41G3 Vibrator Drive
Bad Data
Drive Status
From CF3-41G2 Rotation Drive
Bad Data
Fault Code
From CF3-41G2 Rotation Drive
None / Unknown
Fault Code
From PU3-41G1 Pump Drive
Bad Data
Fault Code
From CF3-41G3 Vibrator Drive
None / Unknown
Other Information
Isolation
Location
Show In VE
Location
Map
Media
Diagram
Maintenance
Comment
CC-MF
Validation
Data Validated
From PU3-41G1 Pump Drive
No
Marker Validated
From PU3-41G1 Pump Drive
No
Relationships
Contains
Multiple Items
Is Inside
Small Coal Dewatering
Is Integrated With
Multiple Items
Is after
Centrifuge E
Is powered by
CF3-41G2 Rotation Drive
Is sent clean coal from
Clean Coal Screen Chute G
Sent sump water to
Centrifuge Concentrate Collection Box G
sends coking coal to
Multiple Items
Show In 3D