Overdense Medium Pump C Dashboard
Home
Overdense Medium Pump C Dashboard
Description / Full Name
Coal Washery
/
Small Coal
/
Medium Recovery
/
Med. Recovery Circuit C
/ Overdense Medium Pump C
Product Pump
Density Monitored
Alarm
On PU3-27C Drive
Circuit Breaker Has Tripped
Alarm
On PU3-27C Drive
Control Supply Has Tripped
Alarm
On PU3-27C Drive
Drive Comms Fault
Alarm
On PU3-27C Drive
Drive Fault
Alert - Faulted
On PU3-27C Drive
There is an active fault on this device.
Alarm
On PU3-27C Drive
MCC Stop
Alarm
On PU3-27C Drive
Process Interlock
Alarm
On PU3-27C Drive
Run Contactor Fault
Alarm
On PU3-27C Drive
Thermal Overload
Tag
PU3-27C
Motor Current
Monitored By PU3-27C Drive
Bad Data
Specific Gravity
Monitored By Overdense Medium Splitter Box Density Transmitter
Bad Data
Drive Mode
Monitored By PU3-27C Drive
Bad Data
Drive Status
Monitored By PU3-27C Drive
Bad Data
Fault Code
Monitored By PU3-27C Drive
Bad Data
Drawing IDs
10018
Drawing Reference
F10
AR Marker
Test AR
Data Explorer
Click To View
Maintenance
View Maintenance System
Properties from Other Assets
Water Pressure
From Fresh Water Ring Main Pressure Tx.
Bad Data
415 Phase A Voltage
From CB4-406 WC2
Bad Data
415 Phase B Voltage
From CB4-406 WC2
Bad Data
415 Phase C Voltage
From CB4-406 WC2
Bad Data
Flow Status
From Overdense Medium Pump Fresh Water Flow Switch
Bad Data
PV Level
From Overdense Medium Sump C Level Transmitter
Bad Data
Fault Code
From Overdense Medium Sump C Level Transmitter
Bad Data
Other Information
Isolation
Location
Show In VE
Location
Show In 360
Location
Map
Media
Diagram
Maintenance
Comment
CC-GF
Job Status
From Overdense Medium Sump C Level Transmitter
Not Started
Job Type
From Overdense Medium Sump C Level Transmitter
None
Service Status
From Overdense Medium Sump C Level Transmitter
In Service
Validation
Data Validated
Monitored By PU3-27C Drive
No
Marker Validated
Monitored By PU3-27C Drive
No
Data Validated
From Overdense Medium Sump C Level Transmitter
No
Marker Validated
From Overdense Medium Sump C Level Transmitter
No
Relationships
Contains
PU3-27C Drive
Is Controled By
Overdense Medium Sump C Level Transmitter
Is Inside
Med. Recovery Circuit C
Is Monitored By
Multiple Items
Is Visible From
Coarse Coal Level 1 - -34.3 x 91.5
Is powered by
PU3-27C Drive
Is sent fresh water from
Overdense Medium Pump Fresh Water Feed Valve
Is sent overdense medium from
Overdense Medium Pump Inlet Valve
sends overdense medium to
Overdense Medium Slurry Flow Transmitter
Show In 3D