ARDI
ARDI
Toggle navigation
185
There are 185 active alerts
ZS1-11.1 Drifting
ZS1-11.2 Drifting
ZS1-21.1 Drifting
ZS1-21.2 Drifting
ZS1-26.2 Drifting
ZS1-26.3 Drifting
ZS1-26.4 Drifting
ZS1-26.5 Drifting
ZS1-29.1 Drifting
ZS1-29.2 Drifting
ZS1-42.1 Drifting
ZS1-42.2 Drifting
ZS1-42.3 Drifting
ZS1-42.4 Drifting
HSS4-46.3 Stopped
ZS1-13.1 Drifting
ZS1-13.2 Drifting
ZS1-14.1 Drifting
ZS1-14.2 Drifting
ZS1-15.1 Drifting
ZS1-15.2 Drifting
ZS1-18.2 Drifting
ZS1-18.3 Drifting
ZS1-18.4 Drifting
ZS1-18.5 Drifting
ZS1-45.3 Drifting
ZS1-45.4 Drifting
ZS1-45.5 Drifting
ZS1-45.6 Drifting
ZS1-46.3 Drifting
ZS1-46.4 Drifting
ZS1-47.3 Drifting
ZS1-47.4 Drifting
ZS1-48.3 Drifting
ZS1-48.4 Drifting
ZS1-6.1 Drifting
ZS1-6.2 Drifting
ZS1-9.1 Drifting
ZS1-9.2 Drifting
ZS2-28.1 Drifting
HSS2-28.13 Pulled
HSS2-28.14 Pulled
ZS2-28.2 Drifting
ZS6-1.2 Drifting
ZS6-1.3 Drifting
ZS6-1.4 Drifting
ZS6-1.5 Drifting
ZS6-6.2 Drifting
ZS6-6.3 Drifting
ZS6-6.4 Drifting
ZS6-6.5 Drifting
ZS6-22.1 Drifting
ZS6-22.2 Drifting
ZS6-3.1 Drifting
ZS6-3.2 Drifting
CF3-41E2 Rotation Drive Isolator / E-Stop Active
CF3-41E3 Vibrator Drive Isolator / E-Stop Active
SN3-52 Drive Isolator / E-Stop Active
PU2-41 Drive Isolator / E-Stop Active
PU7-11 Drive Isolator / E-Stop Active
SN3-13D Drive Circuit Breaker Has Tripped
SN3-13E Drive Circuit Breaker Has Tripped
PU3-41E1 Pump Drive Isolator / E-Stop Active
PU1-33 Drive Circuit Breaker Has Tripped
PU7-13 Drive Control Supply Has Tripped
PU7-13 Drive Isolator / E-Stop Active
CV1-48 Drive Isolator / E-Stop Active
DT1-49 Drive Thermal Overload
DT1-49 Drive Control Supply Has Tripped
PP1-36 Drive Circuit Breaker Has Tripped
VF1-2 Drive Circuit Breaker Has Tripped
PU7-15C Drive Circuit Breaker Has Tripped
LSH2-24.2 Chute Blocked
FN4-38 Faulted
FN4-64C Faulted
SA6-95 Faulted
PU3-57C Drive Faulted
PU3-49C Drive Faulted
PU3-49A Drive Faulted
PU3-57A Drive Faulted
SN3-52 Drive Faulted
PU2-41 Drive Faulted
PU4-2C Drive Faulted
SN3-5G Drive Faulted
PU3-21B Drive Faulted
PU3-9B Drive Faulted
PU7-11 Drive Faulted
SN3-13D Drive Faulted
SN3-13E Drive Faulted
PU3-2B Drive Faulted
PU3-41E1 Pump Drive Faulted
PU3-43 Drive Faulted
PU4-62B Drive Faulted
FL4-60C Drive Faulted
PU4-47C Drive Faulted
PU4-62C Drive Faulted
PU4-63C Drive Faulted
PU4-66C Drive Faulted
PU4-72C Drive Faulted
PP1-72 Drive Faulted
FL4-53B Drive Faulted
PU4-49 Drive Faulted
PU4-74 Drive Faulted
FE7-2B Drive Faulted
PU4-52A Drive Faulted
PU4-56A Drive Faulted
VF7-2C Drive Faulted
PU1-33 Drive Faulted
FN4-38 Drive Faulted
FN4-64C Drive Faulted
PP1-22 Drive Faulted
PU7-13 Drive Faulted
SA6-95 Drive Faulted
CR2-25 Drive Faulted
CV6-22 Drive Faulted
DT6-3 Drive Faulted
CV1-47 Drive Faulted
CV1-48 Drive Faulted
DT1-49 Drive Faulted
PP1-36 Drive Faulted
VF1-2 Drive Faulted
CV1-5 Drive Faulted
VF1-44D Drive Faulted
PU5-9 Drive Faulted
PU6-24 Drive Faulted
PU7-15C Drive Faulted
CN5-11 Drive Faulted
LT4-60B.1 Faulted
LT4-60A.1 Faulted
LT4-11.1 Faulted
LT1-22.1 Faulted
LT1-41A Faulted
LT1-44A.1 Faulted
LT1-44C.1 Faulted
LT1-44D.1 Faulted
LI1-49.1 Faulted
LT1-16A.1 Faulted
LT4-1C.1 Faulted
LT3-26C.1 Faulted
LT3-26A.1 Faulted
LT3-56A.1 Faulted
LT8-30A.1 Faulted
LT8-30B.1 Faulted
LT7-4.1 Faulted
LT7-8.1 Faulted
PDT2-29.1 Faulted
FV4-60C.1 Faulted
FV1-5.1 Faulted
FV4-39A.3 Faulted
FV2-30.1 Faulted
FV3-8C.1 Faulted
FV3-20C.1 Faulted
FV3-25B.1 Faulted
FV3-25B.2 Faulted
FV1-5.2 Faulted
FV4-13C.1 Faulted
FV4-41A.2 Faulted
FV4-41A.1 Faulted
FV4-50A.1 Faulted
FV7-4.1 Faulted
FV7-12.1 Faulted
FV3-5.2 Faulted
FV3-19C.1 Faulted
LCV3-20C.1 Faulted
LCV3-1C.1 Faulted
WT1-29 Faulted
WT1-19.1 Faulted
LIC4-60B.1 Faulted
LIC4-60A.1 Faulted
LIC4-1A.1 Faulted
LIC4-1B.1 Faulted
LIC3-22A.1 Faulted
LIC3-20C.1 Faulted
LIC3-22C.2 Faulted
LIC3-26A.1 Faulted
LIC3-48C.1 Faulted
LIC3-56A.1 Faulted
PIC3-9B.1 Faulted
PIC3-50C.1 Faulted
FIC3-1C.1 Faulted
DIC3-20B.1 Faulted
DIC3-56C.1 Faulted
FV3-16C.1 Faulted
GT1-1 Faulted
License Expires In 9 Days
View all
Guest
Guest
Login
Dewatering Aid Storage Tank Dashboard
Home
Dewatering Aid Storage Tank Dashboard
Description / Full Name
ICWCP
/
Reagent Addition
/ Dewatering Aid Storage Tank
Tank
Level Monitored
Alert - Faulted
On Dewatering Aid Tank Level Transmitter
There is an active fault on this device.
Alarm
On Dewatering Aid Tank Level Transmitter
Measurement Fault
Tag
TK7-14
Upstream Alarm
Upstream Assets In Alarm
PV Level
Monitored By Dewatering Aid Tank Level Transmitter
^%
Liquid Volume
Bad Data
Comment
Drawing IDs
10041
Drawing Reference
F2
AR Marker
Test AR
Isolation
Location
Show In VE
Location
Map
Media
Diagram
Validation
Data Validated
Monitored By Dewatering Aid Tank Level Transmitter
No
Marker Validated
Monitored By Dewatering Aid Tank Level Transmitter
No
Relationships
Contains
Multiple Items
Is Inside
Reagent Addition
Is Monitored By
Dewatering Aid Tank Level Transmitter
Is takes cationic floc from
Multiple Items
Is takes dewatering aid from
Multiple Items
send cationic floc to
Multiple Items
sends dewatering aid to
Multiple Items
Show In 3D