ARDI
ARDI
Toggle navigation
You have no active alerts
View all
Guest
Guest
Login
Coarse Coal Drain Location Diagram
Home
Coarse Coal Drain Location Diagram
Relationships
Coal Washery
/ Coarse Coal Drain
Location
Tree View
Legend
Name
Show All
< Select One >
AC Power
Anionic Flocculant
Best Viewpoint
Blower Air
Cationic Flocculant
Clarified Water
Coarse Coal
Coarse Coal Correct Medium
Coarse Rejects
Coking Coal
Concentrate
Control
Correct Medium
Data
Dewatering Aid
Dilute Medium
Dilute Water
Energy Coal
Fine Coal
Instrument Air
Integrated
Location
Model
Monitors
Overdense Medium
Overflow
Oversized
Plant Air
Profile
Raw Coal
Reagent
Rejects
Requirement
Shutdown Sequence
Small Coal
Startup Sequence
Sump Water
Tailings
Tramps
Type
Utilisation
Vacuum Air
Visible
Water
Location
AC Power
Clarified Water
Coarse Coal
Coarse Coal Correct Medium
Coarse Rejects
Coking Coal
Correct Medium
Dilute Medium
Dilute Water
Instrument Air
Overdense Medium
Plant Air
Sump Water
Location
Coal Washery
Coarse Coal
Coarse Coal Drain
Coarse Coal Correct
Medium Density
Controller
Coarse Coal Correct
Medium Density
Transmitter
Coarse Coal Correct
Medium Pump Inlet
Valve
Coarse Coal Correct
Medium Sump
Coarse Coal Correct
Medium Sump
Clarified Water
Feed Valve
Coarse Coal Correct
Medium Sump Drain
Valve
Coarse Coal Correct
Medium Sump Plant
Air Feed Valve
Coarse Coal Crusher
Coarse Coal Crusher
Discharge Chute
Coarse Coal Product
Screen
Coarse Coal Product
Screen Product
Discharge Chute
Coarse Coal Product
Screen Reject
Discharge Chute
Coarse Coal Product
Screen Underpan
Coarse Coal Product
Static Screen
Coarse Rejects
Screen
Coarse Rejects
Screen Clarified
Water Feed Valve
Coarse Rejects
Screen Discharge
Chute A
Coarse Rejects
Screen Discharge
Chute B
Coarse Rejects
Screen Feed Launder
/ Box
Coarse Rejects
Screen Underpan
Crusher Dust
Collector
Dust Collector
Intake Chute
Magnetics Floor
Sump D
A Module Density
Control Valve
B Module Density
Control Valve
Overdense Medium
Splitter Box
Control Valve #2
Coarse Coal Correct
Medium Pump
Coarse Coal Correct
Medium Sump Level
Transmitter
FV2-30.1 Isolation
Valve
CR2-25 Drive
Coarse Coal Crusher
Home Limit
Coarse Coal Crusher
Speed Sensor
SN2-24 Drive
Coarse Coal Product
Screen Chute A
Blockage Detector
Coarse Coal Product
Screen Chute B
Blockage Detector
Coarse Rejects
Chute Blockage
Detector
SN2-26 Drive
Clarified Water
Isolation Make-Up
PU6-24 Instrument
Air Isolation to
Tank SN2-26
DC2-29 Drive
Dust Collector
Differential
Pressure
Transmitter
Magnetics Floor
Sump D Level High
Switch
Magnetics Floor
Sump D Level Low
Switch
Magnetics Floor
Sump Pump D
Instrument Air
Isolation Overdense
Medium Splitter
BoInstrument Air
Isolation Valves
CV3-28, DCV3-20A.1
& DCV3-20B.1
PU2-31 Drive
PU3-47 Drive
Inside
Contains
DASHBOARD
EXPLORE DATA
LOCAL NETWORK
DASHBOARD